$170.00

Model Number:
AS80-50DP3
Availability:
3
Brand:
AUTONICS

Not yet rated Write a review

Description

Long sensing distance type proximity sensor AS Series can detect a long distance of 50mm and features world-best class superior noise resistance characteristics with exclusively designed IC. Also simultaneous outputs of Normal Open and Normal Close increases user experience.

Main Features

● Sensing up to as 50mm
● Improved the noise resistance with dedicated IC
● Built-in reverse polarity protection circuit,surge protection circuit, overcurrent protection circuit
● Wide range of power supply : 12-48VDC
   (Voltage range : 10-65VDC)
● Simultaneous output of Normal Open+Normal Close
● Built-in power indicator and operation indicator
● Protection structure IP67(IEC standard)

.

Specifications

Model AS80-50DN3 AS80-50DP3
Sensing type NPN Normally Open + Normally Closed PNP Normally Open + Normally Closed
Sensing distance 50mm
Hysteresis Max. 15% of sensing distance
Standard sensing target 150 x 150 x 1mm(lron)
Setting distance 0 to 35mm
Power supply
(Operating voltage)
12-48VDC (10-65VDC)
Current consumption Max. 20mA
Response frequency†1 30Hz
Residual voltage Max. 2V
Affection by Temp. Max. ±10% for sensing distance at ambient temperature 20°C
Control output Max. 200mA
Insulation resistance Min. 50MΩ(at 500VDC megger)
Dielectric strength 1500VAC 50/60Hz for 1 minute
Vibration 1mm amplitude at frequency of 10 to 55Hz(for 1 mln.) in each of X, Y, Z directions for 2 hours
Shock 500m/s²(approx. 50G) in X, Y, Z direction for 3 times
Indicator Power indicator: green LED, Operation indicator: yellow LED
Environment Ambient temperature -25 to 70°C, storage : -30 to 80°C
Ambient humidity 35 to 95%RH, storage :35 to 95%RH
Protection circuit Surge protection circuit, Reverse polarity proteciton circuit, Overcurrent protection circuit
Cable Ø5, 4-wire, 2m(AWG22, Core diameter: 0.08mm, Number of cores: 60, Insulator diameter: Ø1.25)
Approval CE
Protection IP67(IEC standard)
Unit weight Approx. 470g
Document download
†1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.
†Environment resistance is rated at no freezing or condensation.


Dimensions




Connections

Reviews