Autonics Timer, 1/16 DIN, 6 operation modes, 0.05sec - 100hr setting range, 2 SPDT, 24VAC/24VDC, (11 pins socket req'd)

$49.00

Model Number:
AT11EN-2
Availability:
95
Brand:
AUTONICS

Not yet rated Write a review

Description

Free voltage Multi Function timer ATN Series realizes wide range of power supply (100-240VAC 50/60Hz / 24-240VDC, 24VAC 50/60Hz / 24VDC, 12VDC) and control time (0.05sec~100hour) to increase customer’s convenience. Moreover, it is easy to check output status by built-in LED display. The series provides suitable time solution for customers’ environment with 6 kinds of various output operation modes and 16 kinds of time range.

Main Features

  • Realization of wide range of power supply
    :100-240VAC 50/60Hz / 24-240VDC universal, 24VAC 50/60Hz / 24VDC universal, 12VDC
  • Various output operation(6 kinds modes)
  • Multi time range(16 kinds of time range)
  • Wide control time(0.05sec. to 100hour)
  • Easy setting of time, time range, output operation mode
  • Easy to check output status by LED display
  • .

    Specifications

    Model AT8N- AT11EN- AT11DN-
    Function Multi function timer
    Control time setting range 0.05 sec. to 100 hour
    Power supply • 100-240VAC 50/60Hz, 24-240VDC universal  
    • 24VAC 50/60Hz, 24VDC universal
    • 12VDC
    Allowable voltage range 90 to 110% of rated voltage
    Power consumption • 100-240VAC : 4.3VA, 24-240VDC : 2W
    • 24VAC : 4.5VA, 24VDC : 2W • 12VDC : 1.5W
    • 100-240VAC:3.5VA, 24-240VDC:1.5W
    • 24VAC:4VA, 24VDC:1.5
    • 12VDC:1W
    Reset time Max. 100ms
    Min. input signal width START - Min. 50ms
    INHIBIT
    RESET
    Input START - No-voltage input - Short-circuit impedance : Max. 1kΩ
    Residual voltage : Max. 0.5V
    Open-circuit impedance : Min. 100kΩ
    INHIBIT
    RESET
    Timing operation Power ON start type Signal ON Start type
    Control output Contact type Time limit DPDT(2c),
    Time limit DPDT(1c)+
    Instantaneous DPDT(1c) by
    selecting output operation mode
    Time limit SPDT(1c), Instantaneous SPDT(1c) Time limit DPDT(2c)
    Contact capacity 250VAC 5A resistive load
    Relay life cycle Mechanical Min. 10,000,000 operations
    Electrical Min. 100,000 operations(250VAC 5A resistive load)
    Repeat error Max. ±0.2% ±10ms
    SET error Max. ±5% ±50ms
    Voltage error Max. ±0.5%
    Temperature error Max. ±2%
    Insulation resistance Min. 100MΩ(at 500VDC megger)
    Dielectric stength 2000VAC 50/60Hz for 1 minute
    Environ-ment Ambient temperature -10 to 55°C, storage: -25 to 65°C
    Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
    Approval CE, UL
    Accessory Bracket
    Unit weight Approx. 90g
    Document download
    † Environment resistance is rated at no freezing or condensation.

    Reviews