Temp Control, W72 x H36mm, 3 digit display, relay output, Compressor output, RTD, 12-24 VDC

$77.00

Model Number:
TC3YF-11R-R
Availability:
4
Brand:
AUTONICS

Not yet rated Write a review

Description

Freezing / Defrost temperature controller TC3YF series is high reliability temperature controller to protect the object inside the chillers via compressor output so that compressor operation cycle and ON ratio can be set even if errors occurs. This series also prevents loss of frozen efficiency with defrost function to remove frozen ice or frost in the freezer, and increases the efficiency of frozen through various delay time setting.

Main features

  • ON/OFF Control
  • Input specification - Basic specification: NTC(Thermistor), Option: RTD(DPt100Ω)
  • Temperature display range 
  • NTC sensor type: -40.0 to 99.9℃(-40 to 212°F) 
    RTD sensor type: -99.9 to 99.9℃(-148 to 212°F)
  • Supports varioius delay functions for utilize freezing 
  • Auto/Manual Defrost selection function, Start-up delay of compressor, Re-operation delay, Minimum ON time, Delay of defrost-end, Operation delay of evaporation-fan
  • Input correction function
  • Enable to set operation period for protecting compressor in error.
  • .

    Specifications

    Model TC3YF-11R†1 TC3YF-14R†1 TC3YF-21R TC3YF-24R TC3YF-31R TC3YF-34R
    Power supply 12-24VDC 100-240VAC50/60Hz 12-24VDC 100-240VAC 5060Hz 12-24VDC 100-240VAC 50/60Hz
    Allowable voltage range 90 to 110% of rated voltage
    Power consumption Max. 8W  Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA
    Display method 7 Segment(red) LED method
    Character size(WxH) 7.4×15.0mm
    Indication range NTC : -40.0 to 99.9℃(40 to 212°F), RTD : -99.9 to 99.9℃(-148 to 212°F)
    Display accuracy (PV ±0.5% or ±1℃, select the higher one) rdg ±1digit
    Sampling period 0.5sec.
    Input sensor†2 NTC : Thermistor, RTD : DPt 100Ω
    Input line resistance Allowable line resistance is max. 5Ω per a wire
    Control method ON/OFF control(Adjustment sensitivity 0.5 to 5.0℃, 2 to 50°F variable)
    Control output Compressor output
    (250VAC 5A 1a)
    Compressor output (250VAC 5A 1a)
    Defrost output (250VAC 10A 1a)
    Compressor output (250VAC 5A 1a)
    Defrost output (250VAC 10A 1a)
    Evaporation-fan output (250VAC 5A 1a)
    Memory protection Approx. 10 years(When using non-volatile semiconductor memory)
    Insulation resistance Min. 100MΩ(at 500VDC megger)
    Dielectric strength 2000VAC 60Hz for 1 minute(between all external terminal and case)
    Noise resistance ±2kV R-phase, S-phase the square wave noise (pulse width: 1us) by the noise simulator
    Relay life cycle COMP Mechanical : Min. 20,000,000 times, Electrical : Min. 50,000 times(250VAC 5A resistive load)
    DEF Mechanical : Min. 20,000,000 times, Electrical : Min. 100,000 times(250VAC 10A resistive load)
    FAN Mechanical : Min. 20,000,000 times, Electrical : Min. 50,000 times(250VAC 5A resistive load)
    Vibration Mechanical 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours
    Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 10 minutes
    Environ -ment Ambient temperature -10 to 50℃, storage: -20 to 60℃
    Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
    Protection Front part: IP65
    Protection - UL - UL - UL
    Unit weight Approx. 143g
    Document download
    †1. There is no defrost function
    †2. RTD(PT 100Ω) type is customizable.
    † Environment resistance is rated at no freezing or condensation.

    Reviews