Model | SPA- 030-05 | SPA- 050-05 | SPA- 030-12 | SPA- 050-12 | SPA- 030-24 | SPA- 050-24 | SPA- 075-05 | SPA- 100-05 | SPA- 075-12 | SPA- 100-12 | SPA- 075-24 | SPA- 100-24 |
Capacity | 30W | 50W | 30W | 50W | 30W | 50W | 75 W | 100W | 75 W | 100W | 75W | 100W |
Input | Power supply† 5 | 100-240VAC{85-264VAC) | 100-120/200-240VAC(85-132/170-264VAC) switching type |
Frequency | 50/60Hz |
Efficiency† 1 | Min. 60% | Min. 67% | Min. 74% | Min. 80% | Min. 70% | Min. 78% | Min. 72% | Min. 78% | Min. 80% |
Current consumption† 1 | Max. 1.2A | Max. 1,6A | Max. 1.0A | Max. 1.4A | Max. 0.8A | Max. 1.1A | Max. 3.0A | Max. 2.0A | Max. 3.0A | Max. 2.0A | Max. 2.5A |
Output | Voltage | 5VDC | 12VDC | 24VDC | 5VDC | 12VDC | 24VDC |
Current | 6A | 10A | 2.5A | 4.2A | 1.5A | 2 1A | 15A | 20A | 6.3A | 8.5A | 3.2A | 4.2A |
Votage fluctuation range† 4 | ±5% |
Input fluctuation ratio† 2 | Max. ±0.5% |
Load fluctuation ratio† 1 | Max. ±2% | Max. ±1% | Max. ±2% | Max. ±1% |
Ripple | Max. ±1% |
Starting time† 1 | Max. 200ms | Max. 150ms | Max. 250ms |
Holding time† 1 | Min. 10ms | Min. 5ms | Min. 10ms | Min. 5ms | Min. 10ms |
Protection | Inrush current protection | Max. 30A(100VAC) Max. 40A(200VAC) | Max. 20A(100VAC) | Max. 45A(100VAC) /Max. 50A(240VAC) | Max. 35A (100VAC) / Max. 40A (240VAC) | Max. 45A (100VAC) / Max. 50A (240VAC) | Max. 35A(100VAC)/ Max. 40A(240VAC) |
Output overcurrent protection† 3 | Min. 110% | Min. 105% | Min. 110% |
Output overvoltage protection | - | 6.5V ±10% | 16V ±10% | 30V ±10% |
Output short-circuit protection | Max. 5ms | Max. 10ms | Max. 5ms | Min. 10ms | Max. 5ms |
Output indicator | Green LED |
Insulation resistance | Min. 100MΩ(Between all input and output terminals with 500VDC) |
Didlectric strength | For 1 minute at 3.0kVAC 50/60Hz(Between all input and output terminals) |
1 minute at 1.5kVAC 50/60Hz(Between all input terminals F.G) |
Vibration | 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours |
Shock | 300m/s² (approx. 30G) in each of X, Y, Z directions for 3 times |
EMS | Conforms to EN61000-6-2 |
EMI | Conforms to EN61000-6-4 |
Protection | IEC60950, IEC50178 Standard |
Environ-ment | Ambient | -10 to 50°C | -10 to 40°C | -10 to 50°C |
temperature | -25 to 65°C |
Ambient humidity | 25 to 85%RH, storage: 25 to 90%RH |
Approval | CE (except 5VDC) | - |
Unit weight | Approx. 350g | Approx. 400g |
Document download | |
† 1: 100% load for rated input voltage(100VAC).
† 2: Rated input voltage
* SPA-030/050 Series : 100-240VAC(85-264VAC) under 100% of load
* SPA-075/100 Series : 100-120/200-240(85-132/170-264VAC) under 100% of load
SPA-100-05 is under 100% of load for [100-120/200-240VAC(100-132/190-264VAC)].
† 3: Rated input voltage(100VAC).
† 4: Vary voltage by output voltage adjuster, it is changed over voltage variation range(±5%).
† 5: The rated input volatge of SPA-100-05 is 100-120/200-240VAC(100-132/190-264VAC).
† Environment resistance is rated at no freezing or condensation..