Meter, Pulse, LED W72XH36mm, 5 Digit, 13 operation modes, NPN Quintuple output, 100- 240 Vac Supply

$255.00

Model Number:
MP5Y-41
Availability:
6
Brand:
AUTONICS

Not yet rated Write a review

Description

High performance digital pulse meter MP5 Series supports 13 kinds of operation modes to measure various industrial numerical data including Frequency, Absolute ratio, Passing time and Error ratio. (MP5M Series have 11 operation modes only.) Having diverse functions with various output types, the series could be widely used in any industrial fields. 50kHz of high speed response time is another feature to improve user’s convenience.

Main Features
  • 13 kinds of various operation modes :
    Revolution, speed, frequency, absolute ratio, passing time, error ratio, cycle, density, passing speed, error, time width, length measurement, time difference, interval, multiplication(MP5M Series have 11 operation modes)
  • Various output function :
    Relay output, NPN/PNP open collector output, low speed serial output, BCD output, PV transmission, RS485 communication output
  • Various functions :
    Prescale function, data monitoring function, hysteresis function, peak value monitoring function, monitoring delay function, auto zero time setting function, lock setting function, display period delay function
  • Max. display range : -19999 to 99999(MP5M : 0 to 99999)
  • Various display units : rpm, rps, Hz, kHz, sec, min, m, mm, mm/ s, m/s, m/min, m/h, ℓ/s, ℓ/min, ℓ/h, %, counts, etc.
  • Selectable voltage input(PNP) or no voltage input(NPN)
  • 50kHz high speed response
  • .

    Specifications

    Series MP5S-4N MP5Y-24 MP5Y-4 MP5W-4
    Display method 7 Segment LED display(Zero blanking type)
    Character size W4 x H8mm W6.8 x H13.8mm
    Max. indication -19999 to 99999
    Power supply 100-240VAC 50/60Hz 24VDC 100-240VAC 50/60Hz 100-240VAC 50/60Hz
    Allowable operation voltage 90 to 110%
    Power consumption Max. 7.5VA  Max. 6W Max. 7VA Max. 6VA
    Power for external sensor 12VDC ±10%, 80mA
    Input frequency • Solid-state Input: Max. 50kHz(Pulse width : Each over 10µs)
    • Contact input: Max. 45Hz(Pulse width : Over 11ms)
    Input level [Voltage input] High : 4.5-24VDC, Low : 0-1.0VDC, Input Impedance : 4.5kΩ
    [No-voltage Input] Impedance at short-circuit: Max. 300Ω, Residual voltage : Max. 1V, Impedance at open-circuit: Min. 100kΩ
    Measuring range • Mode F1, F2, F7, F8, F9, F10 : 0.0005Hz to 50kHz  • Mode F3 : 0.02s to 3,200s
    • Mode F4, F5, F6 : 0.01s to 3,200s  • Mode F11, F12, F13 : 0 to 4 x 10 Count
    Measuring accuracy
    (23 ±5°C)
    • Mode F1, F2, F7, F8, F9, F10 : F.S. ±0.05% rdg ±1digit
    • Mode F3, F4, F5, F6 : F.S. ±0.01% rdg ±1 digit
    Display period 0.05 / 0.5 /1 / 2 / 4 / 8sec.(lt Is same with period of output update.)
    Operation mode Number of revolution/Speed/Frequency(F1), Passing speed(F2), Cycle(F3), Passing time(F4), Time width(F5), Time defference(F6), Absolute ratio(F7), Error ratio(F8), Density(F9), Error(F10), Length measurement(F11), lnterval(F12), Multiplication(F13)
    † Refer to the M-20 to 23 for the operation mode.
    Prescale function Direct Input method(0.0001x10-9 to 9.9999x109)
    Hysteresis† 1 0 to 9999
    Other functions • Lock setting function
    • Auto-Zero time setting
    function
    • Time unit selection
    function
    • Peak value monitoring
    function
    • Memory protection function
    (Mode F13 applied only)
    • Lock setting function
    • Monitoring delay functionUAuto-zero time setting function
    • Current output range selectlon(Current output type only)
    • Comparative output function(HH, H, GO, L, LL)
    • Time unit selection function
    • Deviation memory function(F output mode applied only)
    • Peak value monitoring function
    • Remote/Local switching function(Communicatlon output type only)
    • Data bank switching function† 2
    • Memory protection function(Mode F13 applied only)
    Main output Triple relay - - 250VAC 3A resistive
    load
    Quintuple relay 3a
    Quintuple relay
    NPN Open collector (Quintuple) 12-24VDC 30mA Max. 12-24VDC 20mA max.
    PNP Open collector (Quintuple)
    Sub output BCD Dynamic - NPN Open collector
    12-24VDC 30mA Max.
    NPN Open collector
    12-24VDC 20mA max.
    Low speed serial output - -
    PV transmission - DC4-20mA Load 600Ω Max. (Response time : Max. 800ms) DC4-20mA Load 600Ω Max.
    RS485 communication - 31 channels, Mutual direction communication function
    Memory protection Non-volatile memory(lnput: Min. 100,000 times)
    Insulation resistance Min. 100MΩ(at 500VDC megger) Between charge part and non-charge part
    Dielectric stength 2000VAC 60Hz 1minute(Between terminals of AC power and case,
    Between terminals of AC power and measuring input terminals)
    Impulse noise stength ±2000VAC R-phase, S-phase the square wave noise(pulse width : 1µs) by the noise simulator, repeat frequency 60Hz
    Vibration Mechanical 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hour
    Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 mln.) in each of X, Y, Z directions for 10 minutes
    Shock Mechanical 300m/s²(approx. 30G) in each of X, Y, Z directions for 3 times
    Malfunction 100m/s²(approx. 10G) in each of X, Y, Z directions for 3 times
    Relay life cycle Malfunction - Min. 10,000,000 operations
    Mechanical - Min. 100,000 operations(250VAC 3Aload current)
    Environ -ment Ambient temperature -10 to 50°C, storage : -20 to 60°C
    Ambient humidity 35 to 85%RH, storage : 35 to 85%RH
    Unit weight Approx. 199.5g
    (approx. 141.5g)
    Approx. 209g
    (approx. 117g)
    Approx. 301.5g
    (approx. 177g)
    Approval CE, UL - CE, UL CE, UL
    Document download
    † 1: The hysteresis setting range is changed by the setting position of decimal point. (Refer to M-25 for hysteresis function.)
    † 2: Data bank switching function Is In MP5W series only.
    † 3: The weight with packaging and the weight in parentheses is only unit weight.

    Reviews

    Write a review